Phased Focused Acoustic Logging Tool

Phased Focused Acoustic Logging Tool

Product Details

Basic Information

Model Diameter (mm) Length (mm) Weight (kg) Pressure (MPa) Working Temp. (°C)
PSK2138 φ38 2190 8.00 20 0–85
PSK2146 φ46 2190 12.0 20 0–85
PSK2155 φ55 1950 15.0 20 0–85

 

Description

This product is a phased-focused single-transmitter dual-receiver logging tool that mainly measures the P-wave velocity of the formation. It has two modes—conventional and full-waveform. The conventional mode outputs 5 channels: acoustic first-arrival amplitude, single-receiver 1 P-wave travel time, single-receiver 2 travel time, dual-receiver P-wave interval transit time, and depth-shift compensated dual-receiver interval time. The full-waveform mode outputs the full waveforms of the two receiver crystals. The trigger threshold can be adjusted by the surface acquisition computer.

 

Specification

Parameter Full Waveform Amplitude Rx1 Travel Time Rx2 Travel Time Dual-Rx Interval Comp. Dual-Rx Interval
Range 0–2 ms 0–1,000 mV 100–700 μs 100–800 μs 125–600 μs/m 125–600 μs/m
Accuracy ≤±5 ≤±5 ≤±5 ≤±5 ≤±5

 