Dual-Lateral Logging

Product Details

Basic Information

Model Diameter (mm) Length (mm) Weight (kg) Pressure (MPa) Working Temp. (°C)
PS2335 Φ60 4230 58.5 40 0–100

 

Description

Dual-lateral logging uses the classical 9-electrode structure to obtain two resistivity logs with different investigation depths: deep lateral and shallow lateral. The principle is that the alternating current emitted by the central main electrode A₀ passes through the formation and returns to the surface electrode (deep resistivity) or to the electrodes A₂ and A₂′ on the probe (shallow lateral). Compensating currents emitted by the guard-electrode pairs A₁ and A₁′ keep the monitor electrodes M₁, M₂ and M₁′, M₂′ at the same electric potential. These equipotential surfaces shape the measuring current into a disc of 2-ft thickness that penetrates deep into the well.

Through careful design, a scientific electrode-array distribution, and advanced modular circuits, it achieves accurate measurement and stable operation.

It is currently widely used in coalfield, coal-bed methane (CBM), shale gas, hydrology, and radioactive uranium deposits, and is one of the mandatory measurement parameters for CBM and shale gas.

 

Specification

Parameter Deep Lateral Resistivity Shallow Lateral Resistivity
Measurement Range 0.1–10 kΩ·m 0.1–10 kΩ·m
Calibration Error ≤ ±5% ≤ ±5%

 